Product description
|
Status
|
Active
|
Article number
|
3616-0020
|
Ports
|
1 x 4-position detachable screw terminal, RS-422/485
1 x 9-pin D-sub, RS-232
1 x RJ-45, Ethernet
|
Description
|
Serial Adapter
|
Warranty period
|
5 Years
|
Reliability prediction
|
Service life, operating
|
Operating, 10 year
|
EMC (Electromagnetic Compatibility)
|
EN 61000-6-2
|
Immunity industrial environments
|
EN 61000-6-4
|
Emission industrial environments
|
EN 55024
|
Immunity IT equipment
|
EN 50121-4
|
Railway signalling and telecommunications apparatus
|
IEC 62236-4
|
Railway signalling and telecommunications apparatus
|
EMC specifications
|
EN 61000-4-2, ESD
|
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV
|
IEC 61000-4-3, RF field AM modulated
|
Enclosure:
20V/m 80% AM (1 kHz), 80 – 2 000 MHz
12V/m 80% AM (1 kHz), 2 000 – 2 700 MHz
|
ENV 50204, RF field 900 MHz
|
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
|
EN 61000-4-4, fast transients
|
Signal ports, ± 2 kV
Power ports, ± 2 kV
|
EN 61000-4-5, surge
|
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line
|
EN 61000-4-6, conducted RF immunity
|
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
|
EN 61000-4-9, pulsed magnetic field
|
Enclosure, 1000 A/m, 6.4 / 16 µs pulse
|
EN 61000-4-29, voltage dips and interruption
|
DC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
|
EN 55022, radiated RF emission
|
Enclosure, class A
|
FCC part 15, radiated RF emission
|
Enclosure, class A
|
EN 55022, conducted emission
|
DC power ports, class B
|
Safety
|
EN 60950-1, dielectric strength
|
Signal port to other isolated ports, 1.5 kVrms 50 Hz 1 min
Power port to other isolated ports, 2 kVrms 50 Hz 1 min
|
Safety
|
UL/CSA/IEC/EN 60950-1, IT
|
Climatic
|
Temperature, operating
|
Operating, –25 to +70°C (–13 to +158°F)
|
Temperature, storage
|
Storage & Transport, –40 to +70ºC (–40 to +158ºF)
|
Humidity, operating
|
Operating, 5 to 95% relative humidity
|
Humidity, storage
|
Storage & Transport, 5 to 95% relative humidity
|
Enclosure
|
Enclosure
|
UL 94, PC / ABS, flammability class V-1
|
Dimensions (W x H x D)
|
34 x 123 x 121 mm (1.33 x 4.84 x 4.76 in)
|
Weight
|
0.2 kg
|
Degree of protection
|
IP 21
|
Cooling
|
Convection
|
Mounting
|
Horizontal on 35 mm DIN-rail
|
Mechanical
|
IEC 60068-2-6, vibration
|
Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
|
IEC-60068-2-27, shock
|
Operating, 15 g, 11 ms
|
Interface specifications, power
|
Rated voltage
|
12 to 48 VDC
|
Operating voltage
|
10 to 60 VDC
|
Rated current
|
250 mA @ 12 VDC
125 mA @ 24 VDC
63 mA @ 48 VDC
|
Rated frequency
|
DC
|
Inrush current
|
0.3 A²s @ 48 VDC, @ 10 ms
|
Startup current
|
-
|
Polarity
|
Reverse polarity protected
|
Redundant power input
|
Yes
|
Isolation to
|
All other 2 k Vrms
|
Connection
|
Detachable screw terminal
|
Connector size
|
0.2 – 2.5 mm2 (AWG 24 – 12)
|
Shielded cable
|
-
|
Interface specifications, RS-422/485
|
Electrical specification
|
EIA RS-485
2-wire or 4-wire twisted pair
|
Data rate
|
300 bit/s to 115.2 kbit/s
|
Data format
|
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
|
Protocol
|
Transparent, optimised by packing algorithm
|
Retiming
|
Not applicable
|
Turning time
|
< 3 bits
|
Circuit type
|
TNV-1
|
Transmission range
|
≤ 1200 m, depending on data rate and cable type (EIA RS-485)
|
Settings
|
120 Ω termination and fail-safe biasing 680 Ω
|
Protection
|
Installation Fault Tolerant (up to ±60 V)
|
Isolation to
|
Power: 2 kV
Ethernet: 1; 1.5 k Vrms
|
Connection
|
Detachable screw terminal
|
Connector size
|
0.2 – 2.5 mm² (AWG 24 – 12)
|
Shielded cable
|
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
|
Conductive housing
|
No
|
Interface specifications, RS-232
|
Electrical specification
|
EIA RS-232
|
Data rate
|
300 bit/s – 115.2 kbit/s
|
Data format
|
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
|
Protocol
|
Transparent, optimised by packing algorithm
|
Retiming
|
Not applicable
|
Circuit type
|
SELV
|
Transmission range
|
15 m / 49 ft
|
Isolation to
|
Power 2 kV
Ethernet 1; 1.5 kVrms
|
Connection
|
9-pin D-sub male (DTE)
|
Shielded cable
|
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
|
Conductive housing
|
Isolated to all other circuits
|
Number of ports
|
1
|
Interface specifications, 10/100BaseTX
|
Electrical specification
|
IEEE std 802.3. 2000 Edition
|
Data rate
|
10 Mbit/s or 100 Mbit/s, auto-negotiated or manually set by DIP-switches
|
Protocol
|
UDP, TCP, ICMP, HTTP and ARP
|
Duplex
|
Full- or half duplex, auto-negotiated or manually set by DIP-switches
|
Circuit type
|
TNV-1
|
Transmission range
|
100 m
|
Isolation to
|
Power 2 kVrms
RS-232 1.5 kVrms
RS-422/485 1.5 kVrms
|
Connection
|
RJ-45 shielded, auto MDI/MDI-X
|
Shielded cable
|
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
|
Conductive housing
|
Isolated to all other circuits
|